• Barajar
    Activar
    Desactivar
  • Alphabetizar
    Activar
    Desactivar
  • Frente Primero
    Activar
    Desactivar
  • Ambos lados
    Activar
    Desactivar
  • Leer
    Activar
    Desactivar
Leyendo...
Frente

Cómo estudiar sus tarjetas

Teclas de Derecha/Izquierda: Navegar entre tarjetas.tecla derechatecla izquierda

Teclas Arriba/Abajo: Colvea la carta entre frente y dorso.tecla abajotecla arriba

Tecla H: Muestra pista (3er lado).tecla h

Tecla N: Lea el texto en voz.tecla n

image

Boton play

image

Boton play

image

Progreso

1/25

Click para voltear

25 Cartas en este set

  • Frente
  • Atrás
For ECG recording we will particularly interested in frequencies above 1 kHz?
(Yes - No)
No
At which frequency range you expect to notice more interferences in an ECG system?
(<100 Hz - >100 Hz)
<100 Hz
Hand-held two-electrode systems for ECG recording do require to contain an instrumentation amplifier with high CMRR in order to reject the common-mode interference coming from the mains (line)?
(Yes - No)
No
Is open-loop gain (A) in an OPAMP typically above 10000?
(Yes - No)
Yes
Is the Slew Rate expressed in [units of voltage/units of time]?
(Yes - No)
Yes
Is the Gain Bandwidth Product expressed in [Units of voltage * units of frequency]?
(Yes - No)
No
Does the conductivity of an ionic solution increase with temperature?
Yes
Do anions have positive charge?
No
Is the conductivity of a 0.9% NaCl aqueous solution approximately two times the conductivity of a 0.45% NaCl aqueous solution?
(Yes - No)
Yes
Is heat dissipated in an ionic solution directly proportional to the electric field magnitude in it?
(Yes - No)
No
In a solution of CaCl2 (calcium chloride), does electro-neutrality imply that in the bulk solution (i.e its interior) the number of calcium ions will be the same than the number of chlorine ions?
(Yes - No)
No
Is the concentration of potassium ions (K+) in the interior of a cell larger than in its exterior?
(Yes - No)
Yes
Will the impedance magnitude of a dense cell suspension be significantly larger at low frequencies (<1kHz) than at high frequencies (>1MHz)?
(Yes - No)
Yes
Will the impedance magnitude of normal saline (0.9% NaCl) be significantly larger at low frequencies (<1kHz) than at high frequencies (>1MHz)?
(Yes - No)
No
Will the 1kHz impedance magnitude of a dense cell suspension be significantly larger at 5ºC than at 37 ºC?
(Yes - No)
Yes
Will the impedance magnitude of a dense suspension of lysed cells (broken down cells) be significantly larger at low frequencies (<1kHz) than at high frequencies (>1MHz)?
(Yes - No)
No
In the case of flat surface electrodes, is the capacitance of the electrical double layer in the order of 10 F/cm2?
(Yes - No)
No
Is sandblasting a mechanical method?
(Yes - No)
Yes
If two identical half-cells (i.e. same metal and same ionic media) with a half-cell potential of E1/2 volts are connected through the ionic medium, what will be the voltage measured between their two electrodes?
(0 Volts - 2E1/2 Volts)
0 Volts
When DC current is applied through an electrolyte solution, mass transfer between the electrodes and the solution can occur?
(Yes - No)
Yes
Is the voltage generated by pH electrode (ISE) linearly dependent on the pH?
(Yes - No)
Yes
is the voltage generated by a potassium electrode (ISE sensitive to K+) linearly dependant on the activity of K+?
No
Imagine you have a fast glass pH sensor (ISE) capable of sensing step pH changes, would you use a standard oscilloscope (of the type you have at lab sessions) to measure the evolution of pH by directly connecting it to the ISE?
(Yes - No)
No
Are Ag-AgCl partially toxic?
(Yes - No)
Yes
Are platinum electrodes considered as polarizable electrodes?
(Yes - No)
Yes